Voltage Drop Calculator - ABYC Amperage Tables

Below you'll find a few helpers along the way to properly sizing your wire or cable. As we are primarilly marine focused we have added some tables regarding the amperages as suggested by the ABYC for the marine environment. These standards might be a bit more strict then those in the automotive environment however, they err on the side of caution and were developed with safety in mind.

The volatge drop calculator will allow you to find the percentage of voltage drop as well as the current delivered at the end of the wire run. In the boating world it is suggested:
3% max voltage drop for conductors providing power to panels and switchboards, navigation lighting, bilge blowers, main DC feeders, and any other circuit where voltage drop should be kept to a minimum
10% max voltage drop on conductors used for general lighting and other non-critical circuits

The ampacity (amperage) tables help to choose the correct size cable to handle the power load for which you are trying to find the correct wiring. There are individual tables for single conductor and multiple conductor runs as current carrying conductors which are bundled together will transfer heat to each other in effect reducing their safe current handling capabilities.

Source: Genuinedealz Home

Voltage Drop Calculatordesigned by Gerald Newton

Allowable Amperage of Current Carrying Conductors under 50V as suggested by the ABYC

Select Copper or Aluminum

Select American Wire Gauge (AWG) Size

Select Voltage

Enter 1-way circuit
length in meters

Enter Load
in amps


Voltage drop

Voltage at load end of circuit

Per Cent voltage drop

Wire cross section in circular mils

There have been 52 visitor(s) during last 30 minutes.

JSC "Your Solar Home"
Moscow, 18, 10-th Parkovaya str
Tel.: +7 (499) 7489064, (495-5041005), email:

You must put a link to this stie if you copy information from this site. See Copyright
Webmaster's e-mail::

:: menu

:: Search


на сайте 

:: TEXT_ICQ

Андрей 379315905

:: banners


Текущие посетители
Яндекс цитирования
 

Directrix.ru - рейтинг, каталог сайтов
Рейтинг@Mail.ru